Wang Gang, Zhang Xinqiang, Xie Mingdian, Zhao Caiqi. Analysis of Seismic and Wind-Induced Vibration Responses of a Super-Long Irregular Terminal Structure Under Multi-Point Excitations[J]. STEEL CONSTRUCTION(Chinese & English), 2025, 40(8): 12-19. doi: 10.13206/j.gjgS25052602
Citation: Wang Gang, Zhang Xinqiang, Xie Mingdian, Zhao Caiqi. Analysis of Seismic and Wind-Induced Vibration Responses of a Super-Long Irregular Terminal Structure Under Multi-Point Excitations[J]. STEEL CONSTRUCTION(Chinese & English), 2025, 40(8): 12-19. doi: 10.13206/j.gjgS25052602

Analysis of Seismic and Wind-Induced Vibration Responses of a Super-Long Irregular Terminal Structure Under Multi-Point Excitations

doi: 10.13206/j.gjgS25052602
  • Received Date: 2025-05-26
    Available Online: 2025-10-27
  • Publish Date: 2025-08-22
  • The T3 terminal building of an airport consists of a central hall and two side corridors, with a total structural outline dimension of 411 m × 416 m. It is composed of a lower concrete high-rise structure and a top long-span steel structure roof. According to the architectural layout, structural joints are set up on both sides of the corridor, which coincide with the extension line of the long side of the hall, thus dividing the overall building into three structural zones. Given its dimensions (411 m in length and 200 m in width), the middle area is a highly complex and ultra-long irregular structure. The seismic wave effect and complex and variable wind load distribution should be fully considered, and the seismic and wind-induced response analysis of the structure should be carried out with multi-point excitation.The first three modes of vibration of the structure are horizontal and vertical vibrations in two directions, exhibiting a relatively regular mode shape distribution. These modes are mainly sensitive to seismic effects in the XY, and Z directions. When analyzing the traveling wave effects of subsequent multi-point excitations, the main directions of the traveling waves are X and Y, and three seismic waves in the XY, and Z directions are simultaneously applied to the structure during each wave propagation. The peak values of the main, secondary, and vertical seismic waves are applied in a ratio of 1∶0.85∶0.65. The total proportion of structural columns with a wave effect coefficient greater than 1.0 is 37%, while that of the roof steel structures is 5%. Due to the good overall stiffness of the steel roof, all gravity loads are transmitted to the structural columns. As a result, the structural columns are more sensitive to seismic motion. The total base reaction force under multi-point excitation is significantly smaller than that under uniform excitation, with a mean ratio of 0.45 between the two. This occurs because, when the traveling wave effect is considered, the vibration phases of individual structural members are inconsistent, leading to partial mutual cancellation during the superposition of base shear forces. The influence coefficients for the structural traveling wave effect are as follows: 1.6 for corner columns, 1.5 for edge columns, and 1.4 for all other columns. The components near the support of the roof steel structure are taken as 1.4, and the rest of the components are taken as 1.2.A numerical wind tunnel analysis was conducted to obtain the wind pressure coefficients on the building surface at various wind direction angles of 0°, 45°, 90°, 135°, and 180°. The results showed a highly irregular wind pressure distribution, resulting from the roof's complex shape and the combination of wind pressure and suction. Therefore, when conducting wind-induced vibration analysis on the roof steel structure, the time-history wind pressure effects at various wind direction angles should be fully considered. Based on the results of wind tunnel numerical analysis, the time-history wind pressure at each point on the roof was extracted and converted into time-history nodal loads applied to the structural analysis model. The analysis showed that the steel roof structure exhibited the maximum vertical displacement under the action of wind pressure time-history loads.Subsequent calculations for the wind vibration coefficient were performed using vertical displacement as the control parameter. The calculated coefficients for the roof steel structure under time-history wind pressure at various wind angles ranged from 1.38 to 1.55. Based on these results, a value of 1.5 is proposed for design purposes.
  • loading
  • [1]
    中华人民共和国住房和城乡建设部. 钢结构设计标准:GB 50017—2017[S]. 北京:中国建筑工业出版社,2018.
    [2]
    中华人民共和国住房和城乡建设部. 建筑抗震设计标准:GB/T 50011—2010[S]. 北京:中国建筑工业出版社,2024.
    [3]
    中华人民共和国住房和城乡建设部. 建筑结构荷载规范:GB 50009—2012[S]. 北京:中国建筑工业出版社,2012.
    [4]
    王洪臣,卢骥,尹龙星,等. 西安城市展示中心长悬挑,大跨度钢结构设计[J]. 建筑结构,2024,54(11):84- 92.
    [5]
    汪之松,刘兴龙,武彦君,等. 考虑SSI效应的输电塔-线体系风振响应简化分析[J]. 西南交通大学学报,2019,54(2):319- 327.
    [6]
    王钢,赵才其,颜鹏. 异型空间桁架+单层网壳复合结构分析与设计[J]. 建筑结构,2022,52(增刊1):597- 602.
    [7]
    谢俊乔,刘宜丰,夏循,等. 成都天府国际机场指廊钢结构设计[J]. 建筑结构,2020,50(19):43- 50.
    [8]
    中华人民共和国住房和城乡建设部. 建筑工程风洞试验方法标准:JGJ/T 338—2014[S]. 北京:中国建筑工业出版社,2015.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (70) PDF downloads(7) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return