留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

体外预应力加固锈蚀网架结构的静力性能提升研究

张微敬 徐志勇 牛功科 董峥

张微敬, 徐志勇, 牛功科, 董峥. 体外预应力加固锈蚀网架结构的静力性能提升研究[J]. 钢结构(中英文), 2026, 41(4): 10-18. doi: 10.13206/j.gjgS25050501
引用本文: 张微敬, 徐志勇, 牛功科, 董峥. 体外预应力加固锈蚀网架结构的静力性能提升研究[J]. 钢结构(中英文), 2026, 41(4): 10-18. doi: 10.13206/j.gjgS25050501
Weijing Zhang, Zhiyong Xu, Gongke Niu, Zheng Dong. Research on the Improvement of Static Performance of Corroded Grid Structures Strengthened with External Prestressing[J]. STEEL CONSTRUCTION(Chinese & English), 2026, 41(4): 10-18. doi: 10.13206/j.gjgS25050501
Citation: Weijing Zhang, Zhiyong Xu, Gongke Niu, Zheng Dong. Research on the Improvement of Static Performance of Corroded Grid Structures Strengthened with External Prestressing[J]. STEEL CONSTRUCTION(Chinese & English), 2026, 41(4): 10-18. doi: 10.13206/j.gjgS25050501

体外预应力加固锈蚀网架结构的静力性能提升研究

doi: 10.13206/j.gjgS25050501
基金项目: 

国家重点研发计划(2023YFC3805603)。

详细信息
    作者简介:

    张微敬,博士,教授,主要从事工程结构抗震及大跨空间结构等方面的研究。Email:zhangweijing@bjut.edu.cn

Research on the Improvement of Static Performance of Corroded Grid Structures Strengthened with External Prestressing

  • 摘要: 网架结构是大跨空间结构中研究最早且广泛应用的一种结构形式。然而,随着使用年限的增长,钢构件在锈蚀作用下遭受损害导致截面削弱,而钢构件截面削弱引起结构承载力、刚度下降,使结构存在安全隐患,因此对该类结构提出有效的加固措施具有重要意义。以一个57.6 m×28.8 m游泳馆锈蚀网架结构为研究对象,采用ABAQUS有限元软件,分析锈蚀对结构静力性能的影响,提出一种由钢索、节点和撑杆组成的交叉索承单元对既有网架结构进行加固的方案,并评估该方案对锈蚀网架结构性能提升的效果。研究表明:锈蚀使网架节点最大竖向位移由62 mm增加至70 mm,增加量较少,锈蚀对网架结构整体刚度影响较小;是否考虑锈蚀,网架结构的最大变形均符合相关规范要求;因锈蚀及设计荷载变化,导致应力超限杆件数量占总杆件数的14.1%;采用交叉索承单元体外预应力加固方案改善了锈蚀网架的静力性能,对于结构刚度有一定提升,结构中应力超限杆件数量减少至总杆件数的4.5%。
  • [1] 董石麟. 我国大跨度空间钢结构的发展与展望[J]. 空间结构,2000(2):3- 13.
    [2] Bradshaw R,Campbell D,Gargari M,et al. Special structures:past,present,and future[J]. Journal of Structural Engineering,2002,128(6):691- 709.
    [3] 董石麟,罗尧治,赵阳. 大跨度空间结构的工程实践与学科发展[J]. 空间结构,2005(4):4- 11.
    [4] Qin G,Xu S,Yao D,et al. Study on the degradation of mechanical properties of corroded steel plates based on surface topography[J]. Journal of Constructional Steel Research,2016,125:205- 217.
    [5] 陈蕙芸,刘红波. 游泳馆环境下拉索的抗锈性能及评估方法[J]. 天津大学学报(自然科学与工程技术版),2019,52(增刊2):107- 113.
    [6] Ahn J,Choi R W,Jeon H S,et al. Residual compressive strength of inclined steel tubular members with local corrosion[J]. Applied Ocean Research,2016,59:498- 509.
    [7] Wang H,Zhang Z,Qian H,et al. Effect of local corrosion on the axial compression behavior of circular steel tubes[J]. Engineering Structures,2020,224:111205.
    [8] Zeinoddini M,Peykanu M,Varshosaz M,et al. Ratcheting behaviour of corroded steel tubes under uniaxial cycling:An experimental investigation[J]. Journal of Constructional Steel Research,2015,113:234- 246.
    [9] Lutes L,Kohutek T,Ellison B,et al. Assessing the compressive strength of corroded tubular members[J]. Applied Ocean Research,2001,23(5):263- 268.
    [10] 王元清,宗亮,石永久,等. 钢结构加固技术研究进展与标准编制[J]. 建筑结构学报,2022,43(10):29- 40.
    [11] 张荣强,刘浩东,律帅驰,等. 既有网架杆件外包钢管加固技术试验研究[J]. 工程抗震与加固改造,2024,46(2):152- 156.
    [12] 聂祺,罗开海,唐曹明,等. 网格结构受屈曲影响压杆套管加固法研究及工程应用[J]. 建筑科学,2019,35(5):130- 135.
    [13] 彭敏,赵仕兴,刘宇鹏,等. 某钢网架加固设计[J]. 建筑钢结构进展,2024,26(5):93- 100.
    [14] 罗永峰,张敬尧. 有初始荷载作用轴压钢构件预应力加固分析方法研究[J]. 工业建筑,2017,47(2):38- 42.
    [15] 刘中华,吴杰,叶翔,等. 某网架结构加固处理方案探讨[J]. 建筑结构,2011,41(6):134- 137.
    [16] 李树林,张津涛,吴元,等. 网架改造加固设计方法[J]. 钢结构,2009,24(11):35- 39.
    [17] 隽敬东,张国龙. 某体育馆网架加固改造实施方案[J]. 建筑结构,2022,52(增刊2):1766- 1769.
    [18] 中华人民共和国住房和城乡建设部. 建筑结构可靠度设计统一标准:GB 50068—2001[S]. 北京:中国建筑工业出版社,2001.
    [19] 中华人民共和国住房和城乡建设部. 建筑结构可靠性设计统一标准:GB 50068—2018[S]. 北京:中国建筑工业出版社,2018.
    [20] 中华人民共和国住房和城乡建设部. 空间网格结构技术规程:JGJ 7—2010[S]. 北京:中国建筑工业出版社,2010.
    [21] 王友德,史涛,徐善华,等. 一般大气环境锈蚀钢柱抗震性能试验与数值分析[J]. 土木工程学报,2021,54(6):62- 78.
    [22] 中国国家标准化管理委员会. 金属和合金的腐蚀 大气腐蚀性 第1部分:分类、测定和评估:GB/T 19292.1—2018

    [S]. 北京:中国标准出版社,2018.
    [23] 中国国家标准化管理委员会. 金属和合金的腐蚀 大气腐蚀性 第2部分:腐蚀等级的指导值:GB/T 19292.2—2018

    [S]. 北京:中国标准出版社,2018.