Research on Mechanical Properties of Inner Sleeve Connected Joint Between Modules of Fabricated Modular Steel Frame
-
摘要: 对装配式模块化钢框架模块间内套筒连接节点进行有限元数值模拟,研究了内套筒与柱壁间隙、内套筒厚度以及内套筒长度对节点承载力的影响,分析了柱壁与内套筒接触力的形成机理和理论计算公式,推导了内套筒与柱壁的接触力计算公式,并与有限元数值计算结果进行对比。研究表明:内套筒与柱壁之间的预留间隙对节点承载力、应力分布以及接触力影响显著,当内套筒与柱壁无间隙时,节点区域柱壁应力分布较为均匀,随预留安装间隙增加,内套筒与柱壁形成不均匀接触应力,节点承载力下降,建议内套筒与柱壁之间的预留间隙不宜超过4 mm;当内套筒厚度大于柱壁厚度时,节点应力分布较为均匀,建议内套筒厚度宜大于柱壁厚度1~2 mm;适当增加内套筒长度有利于节点应力均匀分布,提高节点承载力,建议内套筒应外伸上层梁翼缘和下层梁翼缘各30~50 mm;柱壁与内套筒接触力理论计算式与数值计算结果的误差约为10%,这是由于算式忽略了柱子轴向弯曲变形的影响。Abstract: The finite element numerical simulation of the inner sleeve connected joint between the modules of the fabricated modular steel frame was carried out. The influences of the gap between the inner sleeve and the column wall, the thickness and the length of the inner sleeve on the bearing capacity of the joint were studied. The forming mechanism and theoretical calculation formula of the contact force between the column wall and the inner sleeve were analyzed. The formula for calculating the contact force between the inner sleeve and the column wall was derived and compared with the finite element numerical results. The research showed that the reserved gap between the inner sleeve and the column wall had a significant impact on the bearing capacity, stress distribution and contact force of the joint. When there was no gap between the inner sleeve and the column wall, the stress distribution of the column wall in the joint area was more uniform. With the increase of the reserved installation gap, the contact stress between the inner sleeve and the column wall was uneven, and the bearing capacity of the joint decreased. It is recommended that the reserved gap between the inner sleeve and the column wall should not exceed 4 mm; When the inner sleeve thickness was greater than the column wall thickness, the joint stress distribution was more uniform, it is recommended that the inner sleeve thickness should be greater than the column wall thickness of 1 to 2 mm. Appropriately increasing the length of the inner sleeve is beneficial to the uniform distribution of joint stress and improve joint bearing capacity. It is suggested that the inner sleeve should extend the upper beam flange and the lower beam flange by 30 to 50 mm respectively. The error between the theoretical calculation formula and the numerical calculation result of the contact force between the column wall and the inner sleeve was about 10%, because the influence of axial bending deformation of the column was ignored in formula.
-
[1] 丁阳,邓恩峰,宗亮,等. 模块化钢结构建筑连接节点研究进展[J]. 建筑结构学报,2019,40(3):33-40. [2] 刘佳迪,王剑,陈志华,等. 钢模块建筑单元间连接节点形式综述[C]//第二十一届全国现代结构工程学术研讨会论文集. 天津:2021:163-167. [3] Lee S S, Park K S, Hong S Y, et al. Behavior of C-shaped beam to square hollow section column connection in modular frame[J]. Journal of Korean Society of Steel Construction, 2015, 27(5):471-481. [4] Chen Z, Li H, Chen A, et al. Research on pretensioned modular frame test and simulations[J]. Engineering Structures,2017, 151:774-787. [5] 刘学春,任旭,詹欣欣,等. 一种盒子式模块化装配式钢结构房屋梁柱节点受力性能分析[J]. 工业建筑,2018,48(5):62-69. [6] 邓恩峰,宗亮,丁阳. 钢结构集成模块建筑新型节点力学性能研究[J]. 天津大学学报(自然科学与工程技术版), 2018,51(7):702-710. [7] 刘明扬,王燕,郏书朔. 新型模块化钢框架板式内套筒连接节点力学性能研究[J]. 钢结构,2018,33(1):1-5,10. [8] 中华人民共和国住房和城乡建设部. 建筑结构荷载规范:GB 50009-2012[S]. 北京:中国建筑工业出版社,2012. [9] 中华人民共和国住房和城乡建设部. 建筑抗震设计规范:GB 50011-2010[S]. 北京:中国建筑工业出版社,2010. [10] 王修军,王燕. 装配式梁柱外环板高强螺栓连接节点抗弯承载力研究[J]. 工业建筑,2020,50(11):125-132. [11] 齐威. ABAQUS 6. 14超级学习手册[M]. 北京:人民邮电出版社,2016. [12] 冯鹏,强翰霖,叶列平. 材料、构件、结构的" 屈服点" 定义与讨论[J]. 工程力学,2017,34(3):36-46. [13] 杨咸启,刘胜荣,曹建华. HERTZ接触应力屈服强度问题研究[J]. 机械强度,2016,38(3):580-584.
点击查看大图
计量
- 文章访问数: 299
- HTML全文浏览量: 55
- PDF下载量: 27
- 被引次数: 0