2025 Vol. 40, No. 1
Display Method:
2025, 40(1): 1-17.
doi: 10.13206/j.gjgS24080629
Abstract:
Spatial structures, widely utilized in long-span, large-space, and large-area buildings, playing a significant role in national infrastructure and urban development. China has become a major country in the field of spatial structures, gradually devel...
Spatial structures, widely utilized in long-span, large-space, and large-area buildings, playing a significant role in national infrastructure and urban development. China has become a major country in the field of spatial structures, gradually devel...
2025, 40(1): 18-25.
doi: 10.13206/j.gjgS23091402
Abstract:
Long-span spatial steel structures play an important role in the related fields of human productive activities and life, and large-scale double-layer reticulated shell structures have been widely used in actual projects. Due to the accidental events ...
Long-span spatial steel structures play an important role in the related fields of human productive activities and life, and large-scale double-layer reticulated shell structures have been widely used in actual projects. Due to the accidental events ...
2025, 40(1): 26-33.
doi: 10.13206/j.gjgS23092103
Abstract:
To study the structural response of prestressed double-layer cable flexible photovoltaic brackets under fluctuation wind loads, an analytical solution for cable horizontal tension without considering temperature effects under uniformly distributed lo...
To study the structural response of prestressed double-layer cable flexible photovoltaic brackets under fluctuation wind loads, an analytical solution for cable horizontal tension without considering temperature effects under uniformly distributed lo...
2025, 40(1): 34-41.
doi: 10.13206/j.gjgS23112101
Abstract:
In consideration of the requirements for "normal use", the Aseismic Technical Guidelines Based on Maintaining the Normal Use Function of Buildings (RISN-TG046—2023) incorporates control requirements for "floor horizontal acceleration" by incorporatin...
In consideration of the requirements for "normal use", the Aseismic Technical Guidelines Based on Maintaining the Normal Use Function of Buildings (RISN-TG046—2023) incorporates control requirements for "floor horizontal acceleration" by incorporatin...
2025, 40(1): 42-51.
doi: 10.13206/j.gjgS24070801
Abstract:
In recent years, an increasing number of super high-rise structures have adopted more complex cross-sectional forms (such as variable cross-section, chamfered cross-section, cross-section torsion, etc.) to meet the requirements of aesthetic and iconi...
In recent years, an increasing number of super high-rise structures have adopted more complex cross-sectional forms (such as variable cross-section, chamfered cross-section, cross-section torsion, etc.) to meet the requirements of aesthetic and iconi...
2025, 40(1): 52-57.
doi: 10.13206/j.gjgS23090801
Abstract:
Long-span light-gauge steel industrial buildings are typical wind-induced sensitive structures, which are prone to wind-induced disasters. The wind load is closely related to the shape of the building. Due to functional requirements,long cantilevered...
Long-span light-gauge steel industrial buildings are typical wind-induced sensitive structures, which are prone to wind-induced disasters. The wind load is closely related to the shape of the building. Due to functional requirements,long cantilevered...
2025, 40(1): 58-67.
doi: 10.13206/j.gjgS23122602
Abstract:
Delayed cracks are particularly difficult to detect and can be highly hazardous. Their location is often difficult to predict, and if not identified in a timely manner, the cracks may expand during bridge operation, which usually leads to brittle fra...
Delayed cracks are particularly difficult to detect and can be highly hazardous. Their location is often difficult to predict, and if not identified in a timely manner, the cracks may expand during bridge operation, which usually leads to brittle fra...
2025, 40(1): 68-73.
doi: 10.13206/j.gjgS23110302
Abstract:
This paper studied the method of calculating the length of the vertical rods of steel pipe fully-supported frames with fasteners in construction. The linear interpolation method for calculating the length coefficient in the current specification:acco...
This paper studied the method of calculating the length of the vertical rods of steel pipe fully-supported frames with fasteners in construction. The linear interpolation method for calculating the length coefficient in the current specification:acco...
2025, 40(1): 74-78.
doi: 10.13206/j.gjgS24120420
Abstract:
The cross-sectional classification and the related structural performance factors of European, Japan, AISC and China were briefly reviewed and summarized in the paer. Tabulated values revealed that the classifications of AISC specifications were some...
The cross-sectional classification and the related structural performance factors of European, Japan, AISC and China were briefly reviewed and summarized in the paer. Tabulated values revealed that the classifications of AISC specifications were some...